* Models selection:
STA-115: RT to 1150℃
STA-125: RT to 1250℃
STA-145: RT to 1450℃
STA-155: RT to 1550℃
* From the microscale to largescale samples can be tested (up to 5g); Can meet the test requirements of various samples under different conditions;
* According to the calculation formulas or calculation methods provided by users, we can provide corresponding calculation software in a timely manner.
* All testing procedures be completed automatically, the software can get data like DTA (differential thermal analysis), TG (thermal gravimetric), DTG (derivative thermogravimetric), DDTG, DTA peak area, thermal enthalpy, kinetic parameter, glass transition temperature, specific heat, activation energy and so on.
* Models selection:
STA-115: RT to 1150℃
STA-125: RT to 1250℃
STA-145: RT to 1450℃
STA-155: RT to 1550℃
* From the microscale to largescale samples can be tested (up to 5g); Can meet the test requirements of various samples under different conditions;
* According to the calculation formulas or calculation methods provided by users, we can provide corresponding calculation software in a timely manner.
* All testing procedures be completed automatically, the software can get data like DTA (differential thermal analysis), TG (thermal gravimetric), DTG (derivative thermogravimetric), DDTG, DTA peak area, thermal enthalpy, kinetic parameter, glass transition temperature, specific heat, activation energy and so on.
simultaneous thermal analyzer introduction
The Simultaneous Thermal Analyzer (STA) combines Thermogravimetric Analysis (TG) with Differential Thermal Analysis (DTA) or Differential
Scanning Calorimetry (DSC) to obtain thermogravimetric and differential thermal information simultaneously by using the same sample in the
same measurement. The STA is equipped with various heating furnaces and accessories with different characteristics, covering the vast
majority of materials, including plastics, rubber, synthetic resins, fibers, coatings, oils, ceramics, glass, cement, refractory materials, metals
and alloys, fuels, explosives, pharmaceuticals, food, etc.
simultaneous thermal analyzer features
1. Can automatically control the furnace up/down with accurate positioning, can ensure data reproducibility.
2. By heat flow DSC data gathering way to get the energy and temperature curves.
3. Operators can use standard samples to calibrate the accuracy of temperature, energy, and thermogravimetric.
4. Atmosphere control system uses the Mass Flow Controller (MFC); the triode voltage regulator and steady flow gas can be automatically
switched in the process of experiment with high precision, good repeatability and quick response.
5. From the microscale to largescale samples can be tested (up to 5g); Can meet the test requirements of various samples under different conditions.
6. All testing procedures be completed automatically, the software can get data like DTA (differential thermal analysis), TG (thermal gravimetric), DTG (derivative thermogravimetric), DDTG, DTA peak area, thermal enthalpy, kinetic parameter, glass transition temperature, specific heat,
activation energy and so on.
7. Can take screenshots during testing at any moment, will automatically change the range according to the output signal.
8. The large-screen LCD displays the status and data of the instrument in real time. There are two sets of
thermocouples. One set of thermocouples displays the furnace temperature in real time (whether the heating furnace is working or not) and the other set of thermocouples displays the sample temperature during operation.
9. According to the calculation formulas or calculation methods provided by users, we can provide corresponding calculation software in a timely manner.
10. Self-developed constant temperature controller; constant temperature gas chromatography and mass spectrometry connectors; constant
temperature belt; can fully ensure the secondary detection of tar and various reaction gases.
simultaneous thermal analyzer specfiations
The abscissa axis can choose temperature or time as the scale. | ||
Can choose absolute weight or percentage as the scale for the ordinate axis. | ||
Can be maintained at 1250 degrees or 1550 degrees for 72 hours. | ||
LCD real-time display of furnace temperature, sample temperature, quality, gas path status, etc. | ||
Can plot step cooling curve. | ||
Kinetics of crystallization calculation. | ||
DSC (differential scanning calorimetry) Data | ||
DSC Measuring Range: | ±1mw~±500mw | |
DSC Precision: | ±0.1μw | |
Temperature Data | ||
Models Temperature Range: | model STA-115: RT to 1150℃ model STA-125: RT to 1250℃ model STA-145: RT to 1450℃ model STA-155: RT to 1550℃ | |
Temperature Accuracy: | ±0.1℃ | |
Heating Rate: | 0.1℃/min - 100℃/min | |
TG (thermal gravimetric) Data | ||
Measuring Range: | 1-200mg (0-5g option) | |
Resolution: | 0.1μg | |
Thermogravimetric Noise: | <0.1μg | |
Vacuum Degree: | 2.5×10-2Pa (option with vacuum system) | |
Atmosphere Control System: | Using mass flow controller (MFC), for corrosive gas can be customized. | |
Thermostatic Control System: | constant temperature range: RT - 400 ℃ support extension: STA-GC (gas chromatograph) STA-MS (mass spectrometry) STA-FTIR (fourier transform infrared reflection) | |
DTA (differential thermal analysis) Data | ||
Measuring Range: | ±10μv to ±2000μv | |
DTA Resolution: | 0.01μv | |
Crucibles: | standard: ceramic crucible 0.06ml or 0.12ml option: platinum (Pt), aluminum, graphite and quartz crucible |
PRODUCT CENTER
24 hours:
0086-182.0108.5158
All Rights Reserved © 2015-2025 by Gold APP Instruments Corp. Ltd.
WeChat WhatsApp
GOLD APP INSTRUMENTS CORP. LTD.
HongKong Add: Flat Rm A17, Legend Tower, No. 7 Shing Yip Street, HK, China
Mainland Add: R1302, Baoli Tianyue, Shaowen Rd., Yanta Dist., Xi'an 710077, China
T: +86-182 0108 5158
E: sales@goldapp.com.cn