* Bench-top spray laser particle size analyzer for droplet size testing;
* Adopts Laser diffraction & Fraunhofer diffraction principles;
* Testing range from 1-500μm, 1-1000μm and 1-2000μm;
* Be designed for spray particle and spray droplet size distributions.
* Bench-top spray laser particle size analyzer for droplet size testing;
* Adopts Laser diffraction & Fraunhofer diffraction principles;
* Testing range from 1-500μm, 1-1000μm and 1-2000μm;
* Be designed for spray particle and spray droplet size distributions.
SPRAY-319 Series Spray Particle Size Analyzer Profile
SPRAY-319 Industrial laser particle size analyzer is a specially designed and developed bench-top spray laser particle size analyzer for droplet size test. This instrument adopts laser diffraction & Fraunhofer diffraction principle and parallel light path design with high-performance and high-power laser, lifetime>25000 hours, which can meet the requirements of droplet test easily. The testing range can be adjusted according to the customers’ requirement.
Schematic Diagram of Spray Particle Size Analyzer
SPRAY-319 Series Spray Particle Size Analyzer Features
1. Exclusive Patent Technology
It adopts representative parallel optical testing technology and Spectrum amplification technique, can realize the wide range expansion in limited space. Besides, it adds several auxiliary integration photoelectric detectors, which can effectively collect scattering light from every angle in the testing range, realizing the testing accuracy and reliability in the whole range.
2. Unique Airflow Protection Device
It has airflow protection device, which can effectively protect the lens and avoid droplet pollution to lens in testing process.
3. Split-type Structure Design
Split-type structure and adjustable testing area can meet the needs of the spray test in any conditions and it has many specialties, such as non-contact measurements, non-interfering etc.
4. Stable Automatic Optical Path Alignment System
The optical path alignment system can be corrected by one click, avoid adjustment difficulties caused by the optical path movement.
5. Multiple Size Distribution Models
Offer free choice standard model, RR distribution and Lognormal distribution. Can convert the volume distribution and individual number distribution freely.
SPRAY-319 Series Spray Particle Size Analyzer Specifications
Models | SPRAY-319A | SPRAY-319B | SPRAY-319C | |
Standards | ISO13320-1:1999, GB/T19077.1-2008, Q/0100N001-2013 | |||
Principle | Fraunhofer diffraction principle | |||
Instrument Structure | Split-type | |||
Testing Range | 1μm-500μm | 1μm-1000μm | 1μm-2000μm | |
Number of Channels | 50 pcs | 51 pcs | 58 pcs | |
Accuracy Error | <1% (Reference to CRM D50) | |||
Repeatability Error | <1% (Reference to CRM D50) | |||
Reproducibility | <1% (Reference to CRM D50) | |||
Data Acquisition Rate | ≧2 KHZ | |||
Laser | LD pump laser; λ=532nm, p>40mw, life time>25000 hours | |||
Laser Safety | Class 3B | |||
Air Purging System | Equipped with airflow protection device, can effectively protect the lens, and avoid droplet pollution to lens in testing process. | |||
Sampling Mode | open style | |||
Optical Alignment System | automatic | |||
Working Temperature | 10-40°C | |||
Humidity | ≤75% | |||
PC System | Windows 7/8/10/11 (64 bits) with Office | |||
Output Parameters | Particle volume distribution curve, D10-D100 any parameters | |||
Testing Area Length | 0.1-10 m/adjustable | |||
Lens Protection | Double gas episodic | |||
Outer Dimension | Pkg 1: L369*W295*H360mm, pkg 2: L858*W295*H360mm | |||
Power Supply | 220V, 50HZ | |||
Weight | 68 KG |
test report of SPRAY-319 spray particle size analyzer
Vx: Particle diameter, < X particle volume summation percent of total particle’s volume
Nx: Particle diameter, < X particle number summation percent of total numbers of particles
VAD: The volume weighted average particle size.
SMD: Surface area weighted average particle size.
NAD: The number of weighted average particle size.
R.S: Sample dispersion index, characterization of particle size distribution width. Smaller value, higher concentrated distribution.
N/V: N50/V50, Characterization of particle size distribution width. Values closer to 1, the distribution is more centralized.
Size / quantity distribution: Different statistical analysis
Patents we have:
Pressurized aerosol protection device for spray particle size analyzer is protected by patent No. ZL 2011 2 0267651.9
Spray particle size analyzer with auxiliary probe construction is protected by patent No. ZL 2011 2 0267648.7
Split spray laser particle size analyzer is protected by patent No. ZL 2011 2 0267654.2
Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
3 dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
Mie scattering principle application patent No.- ZL 2013 2 0812021.4.
PRODUCT CENTER
24 hours:
0086-182.0108.5158
All Rights Reserved © 2015-2025 by Gold APP Instruments Corp. Ltd.
WeChat WhatsApp
GOLD APP INSTRUMENTS CORP. LTD.
HongKong Add: Flat Rm A17, Legend Tower, No. 7 Shing Yip Street, HK, China
Mainland Add: R1302, Baoli Tianyue, Shaowen Rd., Yanta Dist., Xi'an 710077, China
T: +86-182 0108 5158
E: sales@goldapp.com.cn