Micro-100 Series BET Surface Area and Pore Size Analyzer

Micro-100 Series BET Surface Area and Pore Size Analyzer

* Dedicated for testing BET surface area, mesopore and micropore;

* Volumetric nitrogen adsorption principle;

* 2 testing stations plus 2 degassing stations, combined as one set with compact size;

* Capable of producing BET, Langmuir, STSA, DR, HK, SF etc. detailed data;

* Every testing procedures and data can be displayed and monitored, all under control.

0.00
0.00
  
PRODUCT DETAILS

* Dedicated for testing BET surface area, mesopore and micropore;

* Volumetric nitrogen adsorption principle;

* 2 testing stations plus 2 degassing stations, combined as one set with compact size;

* Capable of producing BET, Langmuir, STSA, DR, HK, SF etc. detailed data;

* Every testing procedures and data can be displayed and monitored, all under control.


Micro-100 Series BET Surface Area and Pore Size Analyzer Profile


The Micro-100 series BET surface area and pore size analyzer can accurately produce surface area and pore size results of powder materials. According to the different test functions, this series of instruments are divided into three types, there are A, B, and C, the C type is configured with 1 torr or 0.1 torr high-sensitive pressure sensors and turbo molecular pump with ultimate pressure of 10-8 Pa, it can effectively take microporous analysis of microporous materials such as molecular sieve, catalyst, activated carbon, and other microporous materials.  


Micro-100 Series BET Surface Area and Pore Size Analyzer Specifications



Models

Micro-100A

Micro-100B

Micro-100C

Adsorbed Gas

Non corrosive gases, such as N2, Ar, Kr, H2, O2, CO2, CO, NH3, CH4, etc.

Pressure Sensors at Analysis Stations1000 torr1000 torr, 10 torr1000 torr, 10 torr, 1 torr (0.1 torr option)

Pressure Sensor at P0 Station

1000 torr (accuracy: ±0.15% F.S.)

Degas System

 

2 ectopic vacuum heating degas station; samples on analysis stations can be degassed simultaneously.

Degas Temperature

Ambient to 400 Celius, free to set target temperature.

Cold Trap No.

1

Vacuum Pump

 

Two-stage rotary vane mechanical vacuum pump, the ultimate vacuum is 6.7*10-2 Pa

Turbo molecular pump (ultimate vacuum 10-8 Pa) and backup mechanical vacuum pump

Analysis Ports

2 analysis ports can be tested alternately (including P0 test)

Test Principle

volumetric gas adsorption

Specific Surface Area Range

0.0005 m2/g to no upper limit; accuracy within ± 1.0%

0.0001 m2/g to no upper limit; accuracy within ± 1.0%

Pore Diameter Range

 

0.35 nm-500 nm;  

repeatability of pore size is less than 0.2 nm for samples over 2nm.

0.35 nm-500 nm;  

repeatability of pore size is less than 0.2 nm for samples within 0.7 nm - 2 nm micropore.

0.35 nm-500 nm;  

repeatability of pore size is less than 0.2 nm for samples wihtin 0.35 nm - 2 nm micropore.

Minimum Pore Volume

0.0001 cm3/g

Range of Relative Pressure P/P0

10-5-0.998 

10-6-0.998

10-8-0.998

Overall Dimension

depth: 870 mm; width: 570 mm; height: 890 mm; weight: 85 Kgs

Working Temperature

15 - 40 Celius 

Working Humidity

30% - 60%

Electrical Supply

AC220 V ± 20 V, 50/60 Hz, max power 300W


Micro-100 Series BET Surface Area and Pore Size Analyzer Tech Advantages


Temp. Control Module

Internal temperature of test module can be controlled through Real-time monitoring, ensuring accuracy of adsorption detection.


Saturated Vapor Pressure P0        

Using independent P0 pressure sensor for P0 value by inching test, guarantees the reliability of experimental data. Atmospheric pressure input method to determine P0 also be selected. 


Vacuum System

With a multi-channel, adjustable, and parallel vacuum system. Vacuum degree of this system can be controlled in segments. This design prevents samples be vacuumed into analyzer manifolds, meanwhile, a delicate part was designed for ensuring cleanliness of vacuum system, minimizing dust pollution.


Sample Pretreatment System

In addition to two pretreatment stations, the other two analysis stations also can be used for samples pretreatment. There is no interference between pretreatment stations and analysis stations. Pretreatment temperature can be set individually and controlled from ambient to 400 Celius.


Micropore Distribution 

Accurately apply the HK method, SF method and other micropore analysis modules, the error deviation for micropore is less than 0.02 nm.


Pressure Sensor

Micro-100C model equips a 1 torr (0.1torr option) pressure sensor, it makes the partial pressure of P/P0 up to 10-7 - 10-8 (N2/77K) in the physical adsorption analysis.


Cold Free Space

Cold free space can be corrected by Helium automatically, ensuring accuracy of test results. This calibration method is suitable for testing any powder or particle materials.


Control of Liquid Nitrogen Level

Using big volume (3L) Dewar flask and cover with a lid, ensure a constant thermal profile along the length of sample tube and P0 tube throughout testing process.


Turbo Molecular Pump

A turbo molecular pump is a standard configuration part for the Micro-100C model, the ultimate pressure is up to 10-8 Pa, providing a strong support for micropore analysis in the ultra-low pressure range. The smallest micro-pore diameter can be tested is 0.35 nm.



Micro-100 Series BET Surface Area and Pore Size Analyzer Software


  • Micro-100 series software is intelligent in operation control, data acquisition, calculation, analysis and report generation. This software can be communicated with the host through the LAN port and realize remotely control many instruments at the same time. 

  • Software adopts a unique intake control method, the pressure in adsorption and desorption process is optimally set in six- stage; this flexible design is helpful for improving test efficiency. 

  • Changes of the pressure and temperature inside the manifold can be observed directly in the test interface which is convenient for sample test and instrument maintenance. 

  • Current state of analyzer can be intuitively understood with the indicator light and Event Bar.

  • Each adsorption equilibrium process is dynamically displayed on the test interface. Adsorption characteristics of the sample can be easily understood.


Detailed Tabular Reports:

  • Adsorption and desorption isotherms

  • Single-/Multipoint BET surface area

  • Langmuir surface area

  • STSAsurface area 

  • BJH pore size distribution

  • t-plot micropore

  • Dubinin-Radushkevich (DA) micropore

  • Horvath-Kawazoe (HK) micropore

  • Saito-Foley (SF) micropore


Micro-100 series softwareMicro-100 series software 2

Micro-100 series software 3Micro-100 series software 4



Micro-100 Series BET Surface Area and Pore Size Analyzer Testing Reports


Micro-100 Series BET Surface Area and Pore Size Analyzer Report 1Micro-100 Series BET Surface Area and Pore Size Analyzer Report 2

Micro-100 Series BET Surface Area and Pore Size Analyzer Report 3

Micro-100 Series BET Surface Area and Pore Size Analyzer Report 4



  