* High throughput design, can test 4 samples simutaneously;
* Quick analysis time, can complete one sample testing within 20 mins for BET data;
* Support expandable to 8 stations and 12 stations by additional auxiliary units;
* Real time display and control every operation steps, can be fully automatic mode or manul mode;
* One unit combines specific surface area, mesopore size and volume data.
* High throughput design, can test 4 samples simutaneously;
* Quick analysis time, can complete one sample testing within 20 mins for BET data;
* Support expandable to 8 stations and 12 stations by additional auxiliary units;
* Real time display and control every operation steps, can be fully automatic mode or manul mode;
* One unit combines specific surface area, mesopore size and volume data.
Sync-400 Surface Area and Mesopore Size Analyzer Profile
Sync-400 series specific surface area and porosity analyzers are the latest instruments to characterize the surface properties and pore structure for mesoporous materials. The most common and reliable volumetric gas adsorption method is used in Sync-400 series to analyze the adsorption behavior of materials. During the testing, samples share the same Dewar and the same gas source, ensuring the accuracy and repeatability of the analysis, and truly achieving no differential analysis between multiple stations. The master control unit has 4 testing stations, can be expanded to 8 and 12 stations by adding additional auxiliary units. Can realize high performance and high sample throughput.
Sync-400 Surface Area and Mesopore Size Analyzer Features
High Sample Throughput
Up to four samples can be analyzed simultaneously, can complete one sample testing as quick as 20 min for BET specific surface area testing, meeting the requirements of customers with large test requirements in the fields of production and scientific research.
Safety Security
Independently operated safety protection software can remotely monitor the operating status. When analyzer appears abnormal pressure or other dangers, it can automatically control the analyzer and fix problems. Ensure safety to the instrument and operators. Besides, it also equips a protecting door which can prevent the liquid nitrogen splash and protect operators.
Multi-channel Gas Input
The user can choose the multi-channel gas input option, it is convenient for the user to switch freely of various adsorbed gases.
Visual Display of Operating Status
A status display system equipped on the front panel of the instrument; it shows the working diagram of the instrument. The LED lamp of each valve on the display system is used to indicate the on-off of the electromagnetic valve. And the operating process of the instrument can be intuitively observed during the test process.
Independent Vacuum Degasser
Standard configuration with a completely independent vacuum degasser which can prepare the sample by programmable temperature. It is more intelligent, flexible, and convenient for sample pretreatment, and at the same time reduces the time caused by insitu degassing on the analysis position, significantly improving testing efficiency.
Cryo Tune Option
Users can choose Cryo Tune — a low temperature cold bath system. Sync software has Cryo Tune compatible setting, which is convenient for users to test adsorption isotherms at different temperatures.
Sync-400 Surface Area and Mesopore Size Analyzer Software
The newly developed Sync control software is an intelligent software, which implements the operation control, data collection, calculation analysis, and report preview on the Windows platform, and has unique experimental monitoring functions.
Real-Time Monitoring Pressure Balance
The unique adsorption equilibrium pressure intelligent judgment and control method is adopted. Under the condition of sufficient adsorption balance, the test efficiency is much higher than that of the fixed-point method. The software has an independent interface to display the adsorption equilibrium process of each sample in realtime. This can help to understand the adsorption characteristics of the sample in real time, analyze the abnormal phenomena such as gas leakage and insufficient pretreatment during the sample adsorption process, and monitor the operation of the instrument during the experiment.
Adsorption Isotherm
The software has an independent interface to display the adsorption isotherms of each sample in real time, to show the experiment progress and adsorption results in real time, to determine the experimental abnormalities such as air leakage and cold free space changes.
Real-time Display & Record Working Process
Message window can be switched to display, can record experimental control process and software manual operation information of the instrument in realtime, which is benefit for engineers to analyze and remotely diagnose abnormal data.
Data Report:
-Adsorption and desorption isotherm curves;
-BET specific surface area (single-point, multiple-point);
-Langmuir surface area;
-Statistical thickness surface area (STSA);
-BJH pore size analysis;
-t-plot analysis;
Sync-400 Surface Area and Mesopore Size Analyzer Specifications
Model | Sync-400 series |
Test Principle | Static volumetric gas adsorption |
Adsorbate Gas | N2、Ar、Kr、H2、O2、CO2、CO、NH3、CH4 and other non-corrosive gases |
Analysis Port | 4 samples can be tested at the same time, can be expanded to 8 and 12 ports |
Pressure Sensor | 1000 torr |
P/P0 Range | 10-5 - 0.998 |
Surface Area Range | >0.0005 m2/g; repeatability (reference materials) ≤ 1.0% |
Pore Size Range | 0.35nm - 500nm, repeatability (SD) ≤ 0.2nm |
Pore Volume Range | > 0.0001 cm3/g |
Degassing Station | external 4 or 8 stations vacuum degasser |
Degassing Temperature | ambient to 400℃, control precision 1℃ |
Vacuum Pump | two-stage rotary vane mechanical vacuum pump, ultimate vacuum 6.7*10-2 Pa |
Physical | L 510mm × W 530mm × H 930mm, 40 Kg |
Working Temperature | 15 - 35℃ |
Working Humidity | 20% - 80%, non-condensing humidity |
Power Requirements | 100 - 240 VAC, 50/60 Hz, maximum power 300W |
Recommended Applications | battery positive and negative electrode materials, starch and other pharmaceutical auxiliary materials, carbon black, titanium dioxide and other porous powders, alumina, molecular sieve, catalytic materials, activated carbon, zeolite and adsorbent materials. |
There are two types sample degasser be option, PREP 400 and PREP 800, the former one has 4 degassing stations, the later one has 8 stations.
Degassing temperature can up to 400 Celius, control accuracy ±1℃, each degassing station can control temperature independently. Also work with two-stage rotary vane type mechanical vacuum pump, the ultimate vacuum value can reach to 10-2 Pa.
Sync-400 Surface Area and Mesopore Size Analyzer Reports
PRODUCT CENTER
24 hours:
0086-182.0108.5158
All Rights Reserved © 2015-2025 by Gold APP Instruments Corp. Ltd.
WeChat WhatsApp
GOLD APP INSTRUMENTS CORP. LTD.
HongKong Add: Flat Rm A17, Legend Tower, No. 7 Shing Yip Street, HK, China
Mainland Add: R1302, Baoli Tianyue, Shaowen Rd., Yanta Dist., Xi'an 710077, China
T: +86-182 0108 5158
E: sales@goldapp.com.cn