* An intelligent fully automatic wet & dry laser particle size analyzer adopts laser diffraction theory (Mie and Fraunhofer diffraction) to measure size from 0.01μm to 2000μm;
* Compact 2-in-1 design to measure both wet and dry samples;
* Be suitable for both liquid dispersions and dry powders from the nano to the millimeter;
* With both fully automatic and manual control two modes, can be switched freely.
* An intelligent fully automatic wet & dry laser particle size analyzer adopts laser diffraction theory (Mie and Fraunhofer diffraction) to measure size from 0.01μm to 2000μm;
* Compact 2-in-1 design to measure both wet and dry samples;
* Be suitable for both liquid dispersions and dry powders from the nano to the millimeter;
* With both fully automatic and manual control two modes, can be switched freely.
WD-2308A Wet and Dry Laser Particle Size Analyzer Profile
WD-2308A intelligent fully automatic wet & dry laser particle size analyzer adopts laser diffraction theory (Mie and Fraunhofer diffraction), measure size is from 0.01μm to 2000μm (dry 0.1μm-2000μm), which offers reliable and repeatable particle size analysis for a diverse range of applications. It uses dual-beam & multiple spectral detection systems and side light scatter test technology to significantly improve precision and performance of test, It’s the prior choice for industrial production quality control departments and research institutions.
WD-2308A Wet and Dry Laser Particle Size Analyzer Specifications
Model Name | WD-2308A | |
Standards | ISO13320-1:2009, GB/T19007-2016, Q/0100JWN001-2013 Compliance with 21 CFR Part 11 | |
Principle | laser diffraction principle | |
Analysis | Mie and Fraunhofer scattering | |
Detector Arrangement | log-spaced array, test angle from 0.015 degree to 145 degree | |
Measuring Range | wet:0.01μm-2000μm, dry: 0.1μm-2000μm | |
Silicon Photodetectors | wet:127 pcs, dry:100 pcs | |
Accuracy Error | wet<1%, dry<1% (CRM D50) | |
Repeatability Error | wet<1%, dry<1% (CRM D50) | |
Light Sources | high performance semiconductor red laser (λ=639nm) P>3.0MW auxiliary green solid semiconductor laser (λ= 405 nm) P>2.0MW | |
Optical Path | converging light Fourier transform optical path | |
Effective Focal Length | 500mm | |
Laser Safety | class 1 | |
Wet Dispersion | Ultrasonic | frequency:40KHz, power:60W, time: ≥1S |
Stir | revolutions speed: 0-3000RPM (adjustable) | |
Circulate | rated flow:30L/min, rated power:70W | |
Water Level Sensor | prevent water overflow and effectively protect the instrument | |
Sample Tank | volume: 1000ml | |
Micro-Sample Cuvette | volume: 10ml | |
Dry Dispersion | dry-turbulence dispersion patent technology, normal shock wave shear technique | |
Feeding Speed | adjustable | |
Operation Modes | fully automatic / manual control, freely choose | |
Dispersion Medium | compressed air, pressure: 0 to 6 bar | |
Optical Bench Alignment System | fully automatic, precision is up to 0.2um | |
Full Test Speed | wet:<2 Min, dry: <1min, interval time per test result: 500ms | |
Dimension | L104cm x W44cm × H54cm, 70Kg |
WD-2308A Wet and Dry Laser Particle Size Analyzer Advantages
1. Wet and dry sample dispersion system integrated design
WD-2308A intelligent laser particle size analyzer which is 1st set laser particle size analyzer integrated wet and dry dispersion testing as one in China, it successfully resolved the problem of dry and wet technology integration, realize one key to switch, apply to test all particles which particle size distribution from 0.01μm-2000μm.
2. Intelligent fully automatic and manual operation modes can be freely switched
With intelligent automatic mode of operation, to achieve a key test, if according to the prompt addition of sample, click the "test", all process will be complete automatically, not only reduce the testing workload, but also eliminate the interference of human factors, to further improve the accuracy and authenticity of testing results.
Wet method: a key to complete water-supply, ultrasonic dispersion, circulation, testing, cleaning, data record, data analysis, save and print are automatically completed, only take 2 mins.
Dry method: a key to complete the dust collecting, compressed air supply, feeding, testing (the patented technology of turbulence dispersion and the sample window of the negative pressure device make the sample be fully dispersed), data processing and other operation, take 1 min.
3. Stable and unique optical path system
Converging light Fourier transform path patented technology enables scattering light be not restricted to the lens aperture limit, using the double spectral plane optical path design, the photodetector channels can reach 127 pcs, the maximum detection angle is 145 degrees and the minimum detection angle is 0.0155 degrees. Using dual-laser orthogonal light patented technology, the measurement range is effectively extended to 2000 microns. Canon Fourier lens be used to ensure the stability and accuracy of particle measurement.
4. Automatic optical path alignment system
With four hybrid stepping motors in the optical components, precision can be 0.1um, ensure the instrument light path is at its best performance, enhanced the accuracy and stability of test results.
5. Embedded sample wet and dry dispersion system
Auto wet dispersion system can realize one-key operation, be designed mechanical stirring, ultrasonic dispersion, and circulation path as one. It ensures particles uniform dispersion and distribution, avoids many bad phenomena, such as uneven distribution of particles, large particles deposit because of the long outer dispersing system tube, and it guarantees the meaningful of test result
For dry dispersion system, turbulence dispersion patented technology and normal shock shearing effect make particles sufficient dispersion, can test powders range from 0.1 micron to 2000 micron.
6. Instrument software
Patented software system can collect scattering data automatically, make particle testing not be restricted by any functions, truly reflect particles size distribution. The instrument provides high precision data with 10 Khz data acquisition time.
WD-2308A Wet and Dry Laser Particle Size Analyzer Software Features
1. Analysis Modes
Free distribution, R-R distribution, Logarithm normal distribution, mesh number classification etc., can meet various demands of particle size statistic in different industries.
2. Statistic Methods
It has volume distribution and quantity distribution.
3. Statistic Comparison
Several results can be compared by getting results of different batches of samples, like before processing, after processing and different production times. It has great meaning for raw materials quality control.
4. User-defined Analysis
Can produce reports like percentage according to the particle size, particle size according to the percentage, percentage according to the particle size range etc.
5. Report Formats
Word, Excel, Photo (bmp), Text etc.
6. Multiple Languages
Chinese & English (others are option)
7. Intelligent Operation Mode
The system can automatically control water inflow, dispersion, and testing procedures with excellent repeatability.
WD-2308A laser particle size analyzer working schematic
WD-2308A Wet and Dry Laser Particle Size Analyzer Applications
WD-2308A be widely used for particle size related data testing in fields like cement, ceramics, medicines, lotions, paints, dyes, pigments, fillers, chemicals, catalysts, drilling mud, abrasives, lubricants, coal, sediment, dust, cells, bacteria, food additives, pesticides, explosives, graphite, photographic materials, fuel, ink, metal and non-metal powder, calcium carbonate, kaolin, coal slurry and other powdered materials.
Patents we have:
Optical bench design is protected by patent No.- ZL 2014 2 0378380.8,
Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.
MIE scattering principle application patent No.- ZL 2013 2 0812021.4.
Dry particle size analyzer full sealed sample cuvette application is protected by patent No.- ZL.2011 2 0267646.8.
Dual laser beam orthogonal application is protected by patent No.-ZL 2007 2 0025702.0
Powder dispersion pump design application is protected by patent No.-ZL 2007 2 0018648.7
Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2
PRODUCT CENTER
24 hours:
0086-182.0108.5158
All Rights Reserved © 2015-2025 by Gold APP Instruments Corp. Ltd.
WeChat WhatsApp
GOLD APP INSTRUMENTS CORP. LTD.
HongKong Add: Flat Rm A17, Legend Tower, No. 7 Shing Yip Street, HK, China
Mainland Add: R1302, Baoli Tianyue, Shaowen Rd., Yanta Dist., Xi'an 710077, China
T: +86-182 0108 5158