* dynamic light scattering nanometer particle size analyzer;
* calculate particle diameter and distribution according to stokes-Einstein equation;
* get date like average particle diameter, particle distribution, photon counting rate etc.;
* exclusively using dual-wavelength (λ= 450 nm, λ= 532 nm) laser to build the optical system;
* semiconductor temperature control technology, precision control within ±0.1℃.
* dynamic light scattering nanometer particle size analyzer;
* calculate particle diameter and distribution according to stokes-Einstein equation;
* get date like average particle diameter, particle distribution, photon counting rate etc.;
* exclusively using dual-wavelength (λ= 450 nm, λ= 532 nm) laser to build the optical system;
* semiconductor temperature control technology, precision control within ±0.1℃.
DLS-803 Dynamic Light Scattering Particle Size Analyzer Introduction
DLS-803 dynamic light scattering nanometer particle size analyzer which based on the dynamic light scattering principle, Brownian motion principle. It adopts great performance of Japan HAMAMATSU photomultiplier and self-developed high speed digital correlator as core parts, get diffusion coefficient by test scattering light change in some angles, and calculate particle diameter and distribution according to stokes-Einstein equation. The analyzer is with characters of fast calculation, high resolution ration, good accuracy, and repeatability, it’s widely used in company product lab research and university, especially for testing particle size distribution of colored particles.
DLS-803 Dynamic Light Scattering Particle Size Analyzer Specifications
Specs | DLS-803 | |
Standards | GB/T 19627-2005/ ISO 13321:1996, GB/T 29022-2012/ ISO 22412:2008 | |
Measure Range | 1nm - 10000nm (reference to sample) | |
Concentration Range | 0.1mg/ml - 100mg/ml | |
Accuracy Error | <1% (average size of CRM) | |
Repeatability Error | <1% (average size of CRM) | |
Light Source | Semiconductor laser, λ= 532nm P=30 mW Auxiliary blue laser, λ= 450nm P=5.0 mW | |
Detector | PMT -Imported Japan HAMAMATSU photo-multiplier (19-90℃) | |
Scattering Angle | 90o | |
Sample Cuvette | 1 - 4mL | |
Test Temperature | 5-90℃ (temperature controller 5-90℃, precision within 0.1℃) | |
Test Speed | <5 Min | |
Power Supply | 220V 50HZ/60HZ | |
Outer Dimension | L48cm * W27cm * H17cm | |
G.W. | 12 Kgs | |
Operation System (Min) | Win XP, Win 7, Win 10, 64 bits, USB port: 2.0 /3.0 | |
Analysis | Average particle diameter, particle distribution, photon counting rate etc. | |
Digital Correlator | Model | CR256 |
Auto-correlation Channels | 256 | |
Baseline Channel | 4 | |
Unit Delay Time | 100ns-10ms |
DLS-803 Dynamic Light Scattering Particle Size Analyzer Applications
Be used for fields like metallic oxide, metallic powder, ceramic material, protein, polymer latex, preparation of pharmaceutical, water/oil emulsion, paint, coating material, pigment, ink, toner, cosmetics and other fields of research, preparation, and application of nano materials.
DLS-803 Dynamic Light Scattering Particle Size Analyzer Features
1) Dual-wavelength laser, automatic switching:
Exclusively using dual-wavelength (λ= 450 nm, λ= 532 nm) laser to build the optical system. The correlation spectrum detection system is not only small size, but also has strong anti-interference ability, thus ensuring the stability of the test. For some samples with absorbance properties, which cannot be detected by traditional single-wavelength laser, it can be tested effectively.
2) Advanced test principle:
Dynamic light scattering principle and photon correlation spectrum technology, according to Brownian motion speed of particle to test particle size, different size of particles have different speed, when laser illuminate these particles, it will make scattering light happen different speed of fluctuations- downs. Photo correlation spectrum method will analyze these particle size according to Photon fluctuations -downs in particular direction.
3) High resolution:
Using PCR technology test nanometer-scale particle size, must be able to distinguish nanosecond signal fluctuations. The core component of the instrument is CR256 digital correlator be developed by our company, with 8ns high resolution speed.
4) High sensitivity and Noise-signal ratio:
Detector is composed of imported HAMAMATSU photomultiplier, so ensure good accuracy.
5) High speed data collection and calculation:
Self-developed patent product-CR256 digital correlation, It could finish dynamic scattering light intensity collection and autocorrelative function real time calculation, Data processing speed is up to 162M, effectively reflect dynamic scattering light information of different sizes of particles.
6) High stable optical path system:
Photon correlation spectrum detect system adopt optical-fiber technology, smaller size and high anti-interference and reliability.
7) High precision constant temperature control system:
Semiconductor temperature control technology, precision control within ±0.1℃,make samples be in a constant state throughout the testing process, prevent testing error because temperature change will change liquid viscosity and Brownian movement speed.
8) Output parameters:
Real particle size distribution, freely set D10-D100, D [4,3], D [3,2], D [2,1], D [1,0] and specific surface area.
PRODUCT CENTER
24 hours:
0086-182.0108.5158
All Rights Reserved © 2015-2025 by Gold APP Instruments Corp. Ltd.
WeChat WhatsApp
GOLD APP INSTRUMENTS CORP. LTD.
HongKong Add: Flat Rm A17, Legend Tower, No. 7 Shing Yip Street, HK, China
Mainland Add: R1302, Baoli Tianyue, Shaowen Rd., Yanta Dist., Xi'an 710077, China
T: +86-182 0108 5158
E: sales@goldapp.com.cn